Search results for "Impact acceleration"

showing 6 items of 6 documents

Effects of treadmill running and fatigue on impact acceleration in distance running

2014

The effects of treadmill running on impact acceleration were examined together with the interaction between running surface and runner's fatigue state. Twenty recreational runners (11 men and 9 women) ran overground and on a treadmill (at 4.0 m/s) before and after a fatigue protocol consisting of a 30-minute run at 85% of individual maximal aerobic speed. Impact accelerations were analysed using two lightweight capacitive uniaxial accelerometers. A two-way repeated-measure analysis of variance showed that, in the pre-fatigue condition, the treadmill running decreased head and tibial peak impact accelerations and impact rates (the rate of change of acceleration), but no significant differenc…

AdultMalemedicine.medical_specialtyAccelerationPhysical Therapy Sports Therapy and RehabilitationAccelerometerRunningSports EquipmentYoung AdultAccelerationTreadmill runningPhysical medicine and rehabilitationDistance runningAccelerometrymedicineHumansOrthopedics and Sports MedicineForeheadTreadmillMathematicsLegImpact accelerationSignificant differenceBiomechanical PhenomenaShock (mechanics)Muscle FatiguePhysical therapySports Biomechanics
researchProduct

Acute Effects on Impact Accelerations Running with Objects in the Hand

2021

Amateur runners usually run carrying implements in their hands (keys, a mobile phone, or a bottle of water). However, there is a lack of literature about the effects of different handloads on impact accelerations. Thus, this study aimed to analyse the effects of carrying different objects in the hand on impact accelerations during running. Nineteen male recreational runners (age 24.3 ± 6.8 years, training volume of 25 ± 7.38 km/week) performed twenty minutes of running on a treadmill at 2.78 m/s with four different conditions: no extra weight, with keys, with a mobile phone, and with a bottle of water. Impact acceleration and spatio-temporal parameters were analysed through a wireless triax…

Acute effectsmedicine.medical_specialtyimpact accelerationsSciencerunSTRIDEasymmetric handloadsAccelerometerGeneral Biochemistry Genetics and Molecular BiologyArticle03 medical and health sciencesAcceleration0302 clinical medicinePhysical medicine and rehabilitationmedicineEducación Física y DeportivaTreadmillspatio-temporal parametersEcology Evolution Behavior and SystematicsMathematicsImpact accelerationAsymmetric handloadsRunQImpact accelerationsSpatio-temporal parametersPaleontology030229 sport sciencesShock (mechanics)Space and Planetary ScienceMobile phone030217 neurology & neurosurgeryLife
researchProduct

Effect of 3 Weeks Use of Compression Garments on Stride and Impact Shock during a Fatiguing Run

2015

Excessive and prolonged exposure to impact acceleration during running is associated with increased injury rate. Acute use of compressive garments has been speculated to improve attenuation. However, it is unknown how longer interventions of compressive garments influence attenuation in running. 40 runners trained with compressive and placebo stockings for 3 weeks. Perception of comfort, stride parameters (rate, length) and impact acceleration (head and tibial peak acceleration, magnitude, acceleration rate and attenuation) were measured every 5 min during a fatigue run (30 min at 80% of the individual's maximal aerobic speed). Compressive stockings reduced tibial peak acceleration and magn…

AdultMalemedicine.medical_specialtyAccelerationSTRIDEPhysical Therapy Sports Therapy and RehabilitationRunningYoung AdultAccelerationInternal medicineHumansMedicineOrthopedics and Sports MedicineExertionGaitLegImpact accelerationPhysical Education and Trainingbusiness.industryCompression (physics)Biomechanical PhenomenaRate of increaseShock (mechanics)Prolonged exposureMuscle FatigueCardiologyPhysical therapyFemalePerceptionbusinessStockings CompressionInternational Journal of Sports Medicine
researchProduct

Impact Acceleration During Prolonged Running While Wearing Conventional Versus Minimalist Shoes.

2020

Purpose: In recent years a sub-group of minimalist runners have emerged who aim to perform physical exercise more naturally in an attempt to reduce running-related injuries. Here we aimed to determine the effect that running with minimalist footwear in a prolonged run has on footimpact accelerations. Method: Seventeen runners ran with minimalist and conventional shoes (MS and CS, respectively) in two separate sessions; the participants had experience with both footwear types. We measured the length and frequency of each stride, as well as the tibial and head impact acceleration every 5 minutes during a prolonged run (30 minutes at 80% of each individual's maximum aerobic speed). Results: Th…

Foot strikeAdultMalemedicine.medical_specialtyFerides i lesionsAcceleration030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationPhysical exerciseBarefootRunning03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationRisk FactorsmedicineHumansOrthopedics and Sports MedicineImpact accelerationbiologyTibiaCiències de l'esportAthletesFootBiomechanicsBiomecànica030229 sport sciencesGeneral MedicineEquipment DesignEntrenament (Esport)biology.organism_classificationPhysical activity levelBiomechanical PhenomenaShoesNephrologyPsychologyGait Analysishuman activitiesResearch quarterly for exercise and sport
researchProduct

Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmissi…

2021

Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two sepa…

medicine.medical_specialtyDidáctica de la Expresión CorporalComputer scienceAccelerationValidityInstrumented treadmillInstrumented treadmillAccelerometerlcsh:Chemical technologyBiochemistryArticleAnalytical ChemistryRunning03 medical and health sciencesAcceleration0302 clinical medicinePhysical medicine and rehabilitationAccelerometrymedicinerunningHumanslcsh:TP1-1185Electrical and Electronic EngineeringTreadmillGaitInstrumentationReliability (statistics)Impact accelerationspatio-temporalinstrumented treadmillRetrainingReproducibility of Resultsretraining030229 sport sciencesAtomic and Molecular Physics and Opticsimpact accelerationTransmission (telecommunications)Exercise TestRunning economySpatio-temporal030217 neurology & neurosurgerySensors
researchProduct

Effects of Kinesiotape® taping on plantar pressure and impact acceleration during walking

2014

Summary Objectives The aim of this study was to analyse the plantar pressure pattern, contact time, stride rate and impact acceleration in the shank during walking with and without Kinesio Tape (KT®) placed on two muscle groups: peroneus and triceps surae. Methods Among the subjects, 29 (12 men, 17 women) participated in the study. KT® was placed on the triceps surae and peroneus and participants walked at two different speeds (V1: 0.73 m/s; V2: 1.30 m/s) with and without KT®. The pedobarographic system Biofoot IBV® 6.0 was used to analyse plantar pressure (mean peak pressure [kPa]) in 5 foot areas and the kinematic variables of the study (contact time [s]; stride rate [steps/second]). One …

Medial partmedicine.medical_specialtyImpact accelerationbusiness.industryPlantar pressureSignificant differenceSTRIDEKinematicsEntrenament (Esport)Accelerometerbody regionsPhysical medicine and rehabilitationPhysical therapyMedicineOrthopedics and Sports MedicineKinesiotapebusinesshuman activitiesScience & Sports
researchProduct